ROB-8A
Relay Output Card
FEATURES
FUNCTIONAL
DESCRIPTION
This
accessory card mounts outside the host computer and contains
eight Form C electromechanical relays. (Note: Dual
Form C relays are available as an extra-cost option, specify
model number ROB-8A-S02.) This card is provided with
stand-offs and can be mounted on your panel or you can use
Chassis Plans' optional T-Box. ROB-8A receives outputs from Port
A of any 24-bit group of any Chassis Plans digital I/O card and
Readback is provided at Port B pins. Interconnection is
provided by CAB50F-xx ribbon cable.
A
"Polarity Select" switch on the card provides means
to select relay actuation from either high or low logic levels.
An LED associated with each relay illuminates when the adjacent
relay is energized. Also, Port C (high nibble) bits are coupled
to screw terminals on the ROB-8A card for general digital
I/O use. The lower nibble Port C bit PC2 is used for read/write
select. Lower nibble Port C bits PC1 and PC0 are used for
address decoding if more than one ROB-8A card is used on the
same I/O port. As many as four ROB-8A's can be connected to
one 24-bit I/O port. If only one relay card is used, +5 VDC
from the I/O card can power the card. If more than one ROB-8A
is to be used, then there is a jumper that should be removed
and external +5 VDC can be applied at screw terminals on the
card(s).
If
your application requires that the relays be in a known state
at power-up, you may optionally specify additional
2.2 kilohm pull-up or pull-down resistors on the card. If,
for example, you wish all relays to be de-activated at power-up
and you will have the polarity switch set for actuation on
logic HIGH inputs, then you will want pull-down resistors
installed. You may specify this with model number ROB-8A-S04.
Conversely, if you intend to set the switch for actuation
on logic LOW inputs, then you will want pull-up resistors
installed and you may specify this with model number ROB-8A-S03.
Relay
outputs are brought out to eight sets of labeled screw terminals.
The relays used are UL-recognized, non-latching, polarized
units designed to FCC Part 68 isolation requirements. These
relays can switch up to two amperes DC current with a resistive
load or 1.25 amperes AC. Relays in sockets for easy replacement
are available as an extra-cost option, specify model number
ROB-8A-S01.
SPECIFICATIONS
Relays
- Contacts:
Form C, SPDT, non-latching (DPDT optional)
- Contact
Material: Gold overlay silver
- Max.
Switched Current: 2A DC, 1.25A AC
- Max.
Carry Current: 2A, AC or DC
- Max.
Switched Voltage: 125 V DC or AC RMS
- Max.
Switched Power: 30W (DC), 60VA (AC)
- Operate
Time @ nominal voltage: 6 millisecond max (including
bounce)
- Release
Time @ nominal voltage: 8 milliseconds max (including
bounce)
- Mechanical
Life Expectancy: 20 million operations min.
Environmental
- Operating
temperature Range: 0o to 50oC.
- Storage
Temperature Range: -30o to +105oC.
- Humidity:
45 to 85% RH, non-condensing.
| Part
Number |
Price(USD)
|
| ROB-8A |
125.00
|
| Option S01 |
75.00
|
| Option S02 |
30.00
|
| Option S03 |
N/C
|
| Option S04 |
N/C
|
View / Download Manual (in .PDF