Custom Products ProductsIntegration ServicesUser InformationCompany Information
Configured System Quote Form Configured System Quote Form Configured System Quote Form
Products
Home
Systems & Solutions (pdf)
Configured System Quote Form
Product Quote Form
Configured Rackmount Systems
Military Grade Computers & Systems
Rackmount Enclosures 1U-6U
·
- M2U-20A 2U
- M4U-19A 4U
- M4U-20A 4U
- MQS4U-20A 4U
·
- R4U-20A 4U
·
- F1 1U
- F2 1U
- F5 1U
- F6 1U
- F6000 1U
- F8 1U
- F9 1U
- F10 1U
- F11 1U
·
- E1 2U
- E1000 2U
- E2 2U
- E4 2U
- E7 2U
- E9 2U
- E10 2U
- E11000 2U
- E30 2U
- E31 2U
·
- D1 3U
- D2 3U
- D5 3U
·
- C3 4U
- C3000 4U
- C5 4U
- C5000 4U
- C6 4U
- C6000 4U
- C7 4U
- C7000 4U
- C9 4U
- C9000 4U
- C15000 4U
·
- B2 5U
- B2000 5U
·
- A2 6U
- A2000 6U
- Rack Slides
Rackmount LCDs & Keyboards
Portable Computers
Industrial Fanless Computers
Rackmount Disk Array
PCI-E Expansion Systems
Single Board Computers
Passive & Active Backplanes
Industrial Motherboards
Wallmount Chassis
Site Map
Contact Us
Configured System Quote Form
Product Quote Form

    C7000 Series 4U

  • 4U x 26.4 inch depth design
  • Six 5.25 inch external drives
  • One 3.5 inch external drive
  • One internal 3.5 inch drive
  • Two optional internal 3.5 inch drives
  • Four hot swap 51CFM cooling fans
  • 14-slot backplane
  • Various power options
  • Custom paint and logo available
  • Configured System Offered
C5 4U Rackmount Case
Additional Photos

The C7000 Series chassis represent the next generation of RAID capable server chassis providing high performance in a low cost 4U rackmount enclosure. Feature rich, the C7000 Series is a solid, robust design which will meet the most rigorous and demanding requirements.

The enclosure is constructed of 18 gauge steel, clear zinc plated for corrosion protection and an attractive appearance. The front panel is attractively detailed and is of heavier gauge than the chassis.

There is a huge amount of drive storage with the provided six front accessible 5-1/4 inch drive bays, one front accessible 3-1/2 inch drive bay, one internal 3-1/2 inch drive mounting and two optional internal 3-1/2 inch drives. Low cost drive carriers can be used to build a RAID instead of using expensive SCA SCSI drives.

A full width lockable door covers and protects the drives. Accessible behind the door is the power and reset switches. The drive and alarm LED's are mounted on the door.

A full width filter is provided behind the door and is easily accessed for cleaning. Cooling is provided by four 90mm 51CFM hot swap fans.

An optional alarm status board monitors fan operation and chassis temperature. An alarm is sounded and contact closure is available for an alarmed state.

The C7000 Chassis accepts a 14-slot passive backplane. An innovative card hold-down mechanism assures cards stay seated in high-G environments such as shipping.

Click here for companion single board computers.


Downloadable PDF files
  C7000 Datasheet C7000 (14-Slot) Drawing  

Highlights

Dimensions

19" (wide) x 4U (6.95") (high) x 26.4" (deep)

Drive Capacity

Six horizontal 5-1/4 inch half height drives - front accessible
One horizontal 3-1/2 inch x 1 inch drive - front accessible
One internal 3-1/2 inch drive mounted vertically
One optional internal 3-1/2 inch drive mounted vertically

The drive cages are suspended on anti-vibration mounts.

Front Panel Controls

Power switch - large black momentary with 2 position .100 header for board connection
Reset switch - four small black momentary with 2 position .100 header for board connection*
Power Supply Alarm - small black momentary with 2 position .100 header
Power - green LED with 3 position .100 header for board connection
Drive Activity - two green LED's with 2 position .100 header for board connection
Fan Status - two green LED's
System Fault - green LED

Switch and LED connectors are labeled at the connector end.
* Resets provided for up to 4 independant CPU's using a segmented backplane

Rear Panel Details

14 Plug-in card slots
Knockouts for 2 DB9 connectors

Cooling

Four hot swap 90mm 51CFM fans
Positive chassis pressure
30PPI filter installed
Fan Options: thermister regulated fan speed

Alarm Board

Optionally available
Fan operation
Chassis temperature
Redundant power supply failure

Power Supply

PS/2 form factor - not provided
PS/2 Style supply
AC Input - Zippy HG2, HP2, PSM, PSL, AX2, SP2, LP2, MP2, SPE
Redundant AC Input - Zippy MRT, MRP, MRW, MRG,
DC Input - Zippy DB2 (24VDC), DD2 (48VDC), MB2 (24VDC), MD2 (48VDC)

Passive Backplane (C7000 Models)

14-Slot ISA/PCI accommodated

Rack Slides

See Rack Slides for an offering of available slides.


Chassis Plans is more than a chassis supplier. Our primary business is providing long life span fully integrated turnkey systems tailored exactly to customer specification. We are experts at multi-vendor integration and offer a complete product line including the latest long-life motherboards, drives, video boards and plug-in cards including analog/digital I/O cards. Integrating today's complex systems can be a challenge. Allow us to provide you with a professionally integrated system with the OS loaded and the system tested and burned-in as a complete unit. We stand behind our work 100%.

 

 
 